Designazione |
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
n1 [min-1] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
Sistema di Misura |
CP 07 2 7.5
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
7.5 |
1400 |
186.0 |
51.0 |
1.0 |
0.96 |
0.0 |
0.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
7.5 |
n1 [min-1]
1400 |
n2 [min-1]
186.0 |
Mn2 [Nm]
51.0 |
n1 [min-1]
1400 |
Pn1 [kW]
1.0 |
ηd [%]
0.96 |
Rn1 [N]
0.0 |
Rn2 [N]
0.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 2 8.0
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
8.0 |
1400 |
175.0 |
55.0 |
1.0 |
0.96 |
0.0 |
800.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
8.0 |
n1 [min-1]
1400 |
n2 [min-1]
175.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
1.0 |
ηd [%]
0.96 |
Rn1 [N]
0.0 |
Rn2 [N]
800.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 2 9.2
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
9.2 |
1400 |
152.0 |
55.0 |
0.9 |
0.96 |
0.0 |
800.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
9.2 |
n1 [min-1]
1400 |
n2 [min-1]
152.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.9 |
ηd [%]
0.96 |
Rn1 [N]
0.0 |
Rn2 [N]
800.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 2 9.96
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
9.9 |
1400 |
142.0 |
55.0 |
0.8 |
0.96 |
0.0 |
800.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
9.9 |
n1 [min-1]
1400 |
n2 [min-1]
142.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.8 |
ηd [%]
0.96 |
Rn1 [N]
0.0 |
Rn2 [N]
800.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 3 21.0
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
21.0 |
1400 |
67.0 |
55.0 |
0.4 |
0.94 |
0.0 |
1600.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
21.0 |
n1 [min-1]
1400 |
n2 [min-1]
67.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.4 |
ηd [%]
0.94 |
Rn1 [N]
0.0 |
Rn2 [N]
1600.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 3 22.5
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
22.5 |
1400 |
62.0 |
55.0 |
0.4 |
0.94 |
0.0 |
1600.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
22.5 |
n1 [min-1]
1400 |
n2 [min-1]
62.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.4 |
ηd [%]
0.94 |
Rn1 [N]
0.0 |
Rn2 [N]
1600.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 3 26.0
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
26.0 |
1400 |
54.0 |
55.0 |
0.3 |
0.94 |
0.0 |
1600.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
26.0 |
n1 [min-1]
1400 |
n2 [min-1]
54.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.3 |
ηd [%]
0.94 |
Rn1 [N]
0.0 |
Rn2 [N]
1600.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 3 28.1
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
28.1 |
1400 |
50.0 |
55.0 |
0.3 |
0.94 |
0.0 |
1600.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
28.1 |
n1 [min-1]
1400 |
n2 [min-1]
50.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.3 |
ηd [%]
0.94 |
Rn1 [N]
0.0 |
Rn2 [N]
1600.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 3 32.9
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
32.9 |
1400 |
43.0 |
55.0 |
0.2 |
0.94 |
0.0 |
1600.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
32.9 |
n1 [min-1]
1400 |
n2 [min-1]
43.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.2 |
ηd [%]
0.94 |
Rn1 [N]
0.0 |
Rn2 [N]
1600.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |
CP 07 3 38.9
Procedi per completare la configurazione
i |
n1 [min-1] |
n2 [min-1] |
Mn2 [Nm] |
Pn1 [kW] |
ηd [%] |
Rn1 [N] |
Rn2 [N] |
PT [kW] |
Layout |
Tecnologia |
$ |
Lead Time |
38.9 |
1400 |
36.0 |
55.0 |
0.2 |
0.94 |
0.0 |
1600.0 |
0.0 |
IN-LINE |
Helical-Gear |
|
|
|
|
i
38.9 |
n1 [min-1]
1400 |
n2 [min-1]
36.0 |
Mn2 [Nm]
55.0 |
n1 [min-1]
1400 |
Pn1 [kW]
0.2 |
ηd [%]
0.94 |
Rn1 [N]
0.0 |
Rn2 [N]
1600.0 |
PT [kW]
0.0 |
Layout
IN-LINE |
Tecnologia
Helical-Gear |
$
|
Lead Time
|
Sistema di Misura
METRIC |